Which thermodynamic water heaters are compatible with Dualsun SPRING panels?
For a thermodynamic water-heater to be compatible with our SPRING panels, it must be equipped with:
an extra heat exchanger immersed in the bottom of the tank to hydraulically connect the SPRING panels + solar station + thermodynamic tank assembly.
an available immersive sleeve to insert the temperature sensor at the bottom of the tank, at the level of the solar exchanger. This sensor is necessary to control the solar system by activating or not the solar circulator.
Possibility to set operating time slots. This is important in order to optimize the thermal solar production
And ideally (not mandatory) a dry contact external signal input which allows to wire the tank's electronic card to the solar regulator.
Here is the non-exhaustive list of thermodynamic solar water-heater studied for coupling with DualSun SPRING panels (we have classified them in two tables: compatible and non-compatible):
COMPATIBLE with control optimisation
Brand | Model | Possibility to set operating time slots | Possibility to wire the electronic card to the solar regulator |
Yes | Yes | ||
Yes | Yes | ||
Yes | Yes | ||
Yes | Yes | ||
Yes | No | ||
Yes | No | ||
Yes | Yes | ||
Yes | Yes | ||
Yes | No | ||
Yes | No | ||
Yes | No | ||
Programming the schedule is not possible, it is therefore mandatory to use and external clock to pilot the heat pump (Click here) |
NOT COMPATIBLE
Brand | Model | Remark |
No internal heat exchanger | ||
No internal heat exchanger | ||
No place to immerse the temperature probe in the water tank of the water heater to control the solar regulation | ||
No internal heat exchanger | ||
No internal heat exchanger | ||
EKHH2E200AAV3 & EKHH2E200AAV3 | No internal heat exchanger | |
No internal heat exchanger | ||
Kaliko TWH 200 E & TWH 300 E | No internal heat exchanger | |
SHP-A 220 Plus & SHP-A 300 Plus & SHP-F 220 Premium & SHP-F 300 Premium | No internal heat exchanger | |
No possibility to set operating time slots | ||
No place to immerse the temperature probe in the water tank of the water heater to control the solar regulation | ||
No internal heat exchanger | ||
No internal heat exchanger | ||
No internal heat exchanger | ||
No internal heat exchanger | ||
Range Odysee (split version) | No internal heat exchanger | |
MARINA (split version) | No internal heat exchanger | |
No internal heat exchanger | ||
Zibro (ex Qlima) A2W300 | Heat exchanger too high |