How to install SPRING4 on a steel deck roof?
In the case of a steel deck roof, certain precautions must be taken:
It is necessary to ensure that the manifold is not in conflict with an undulation: the layout must be carried out so that the manifold is located between two waves or ensure that the wave height of the steel tank a is less than the distance between the sheet metal of the steel tank (hollow of the wave) and the bottom of the manifold b (function of the installation system):
Landscape mode with vertical rails:
Portrait mode with horizontal rails
It is necessary to ensure that the wave height of the steel tank a is less than the distance between the sheet metal of the steel tank (hollow of the wave) and the bottom of the manifold b (function of the installation system).
In landscape mode with horizontal rails:
This configuration is not possible
In portrait mode with vertical rails :
This configuration is not possible