How to install the inlet - outlet fittings kit on the DualQuickfit hydraulic links?

Edited

1. Pressurized system

A kit of brass inlet / outlet fittings is used to connect the inter-panel links to the transfer circuit.

  • M3/4’’ for DN15 inter-panel links

  • M1’’ for DN26 inter-panel links

This kit includes, for a line of panels:

  • 2 corrugated fittings

  • 4 hose clamps

  • 2 high temperature fiber O-rings

  • 2 screw caps

contenu_kit.png

 

These fittings are installed at the inlet and outlet of each line of sensors.

 

Assembly of the clamp:

  • Place the clamp on the hose 

  • Insert the barbed fitting into the hose (1 & 3)

  • Tighten up to the stop (2 & 4)
    <!> Do not squeeze any tighter


 


 

The inlet / outlet fitting kit is to be installed as specified below:


Simplified diagram installation of a hydraulic line with 4 panels in portrait




Simplified diagram installation of a hydraulic line of 2 panels in landscape

1.  Hydraulic inlet

2. Hydraulic outlet

3. DualQuickfit / Transfer circuit connection

4. DualQuickfit link plug

 

The fluid must flow from bottom to top in the panels.

Respect the hydraulic connection direction (3) at the inlet (1) and at the outlet (2), as shown in the diagrams above and in the table below.

 

Hydraulic inlet (1)

Hydraulic outlet (2)

Portrait

Bottom left

Top right

Landscape

Bottom right

Top left

 

2. Pool system

A kit of compression inlet / outlet fittings for the DN26 inter-panel links allows the inter-panel links to be connected to the transfer circuit.

This kit includes, for a line of panels:

  • 2 x D32/40 mm compression fittings

  • 2 x D32 mm compression caps

kit_de_raccords_entr_e_sortie_PISCINE.png

 

These fittings are installed at the inlet and outlet of each line of panels.

 

The inlet / outlet fitting kit is to be installed as specified below:



Simplified diagram installation of a hydraulic line with 4 panels in portrait

1.  Hydraulic inlet

2. Hydraulic outlet

3. DualQuickfit / Transfer circuit connection

4. DualQuickfit link plug

 

To authorize the winter draining of the direct pool heating system, the DualSun SPRING panels must imperatively be installed in portrait. The fluid must flow from bottom to top in the panels.


Respect the hydraulic connection direction (3) at the inlet (1) and at the outlet (2), as shown in the diagrams above and in the table below.

 

 

Hydraulic inlet (1)

Hydraulic outlet (2)

Portrait

Bottom left

Top right

 

For more information, click here : How do DualQuickFit interpanel connectors work?

 

 

 