Does Dualsun panels certification include hail tests?

Edited

Our panels are all certified at least according to the IEC 61215:2016 standard which requires resistance to the fall of a hailstone 25mm in diameter at a speed of 23 m/s with 10 points of impact.

On the scale of hail resistance classes, this requirement is between RG3 and RG2.

 

Class of resistance

Diameter (mm)

Mass (g)

Speed (m/s)

Impact Energy (J)

RG2

20 (±2%)

3,6 (±5%)

19,5

0,7

IEC 61215:2016 (MQT17)

25 (±2%)

15 (±5%)

23

1,99

RG3

30 (±2%)

12,3 (±5%)

23,9

3,5

RG4

40 (±2%)

29,2 (±5%)

27,5

≥ 11,1

RG5

50 (±2%)

56,9 (±5%)

30,8

≥ 27,0

 

It is important to note that it is not so much the diameter of the hailstone that matters but the energy of the impact.

 

Some of our panels like SPRING 425 Shingle Black or FLASH 410 Half Cut Glass-Glass have higher resistance levels. To see the details of the certifications according to our panels, you can consult this summary table.

 

Panel

Certification 

SPRING 425 Shingle Black

RG4

FLASH 410 Half-Cut Glass-Glass

RG3

FLASH 425 Half-Cut Glass-Glass TOPCon

RG3

FLASH 415 Half-Cut White

IEC 61215:2016 (MQT17)

FLASH 500 Half-Cut Black

IEC 61215:2016 (MQT17)

FLASH 500 Half-Cut Glass-Glass TOPCon

IEC 61215:2016 (MQT17)

FLASH 375 Shingle Black

RG4

FLASH 375 Half-Cut Black

IEC 61215:2016 (MQT17)

SPRING 375 Shingle Black

RG4

SPRING 400 Shingle Black

RG4

FLASH 425 Shingle Black

RG4

FLASH 400 Shingle Black

RG4

FLASH 380 Half-Cut White

IEC 61215:2016 (MQT17)

FLASH 405 Half-Cut White

IEC 61215:2016 (MQT17)

 

> To learn more, read our article : What are the certifications of the Dualsun panel?