What should I prepare for a Dualsun installation in the case of a new construction or a major renovation?
To help you devise your plans or as part of your building permit application, you must take the following into consideration:
The physical characteristics of the panels: the dimensions of the Dualsun hybrid panel are 1 x 1.67m; the weight of each is 30kg
Depending on the size of the installation, plan for an area of between 10 and 15 m² on average. Depending on your geographical location, we size according to hot water needs (DHW) of 1 to 1.5 panel/person
Superimposed (the panels on the tiles): the panels are on average between 4 and 7 cm above the roof
Integration (the panels replace the tiles): here is a video of the assembly of the EASY ROOF structure necessary to integrate the Dualsun panels into the roofing
Some visuals of panels integrated into a roof
The orientation and the incline of your future roof: : our recommendations are here
Shadows which can negatively impact the performance of your installation
Before beginning the construction or major renovation, it is important to plan to plan the piping to the roof: this involves putting in sheaths to pass the water pipes and photovoltaic cables from the machine room to the roof at the time of construction (or renovation).
The diameter of the hydraulic pipes depends on the number of panels. To choose the size of the sheath housing the pipes, you can consult our sizing charts for pipes. These pipes must be protected by thermal insulation at least 1 cm thick.
This can save labor time and thus the budget for the final cost of the installation. In order to better understand what a DualSun installation can offer you depending on the specifics of your home, we recommend that you carry out a personalized and free study on our MyDualsun planning platform.
Finally, some photos of our installations are available on this page: https://dualsun.com/en/realisations/
In the technical room, what volume is necessary for a Dualsun installation ?
Component | Location | Dimensions |
Solar tank 300 L | Ground surface and heigth | Diamètre 700 mm ; Hauteur 1480 mm |
Solar tank 500 L | Ground surface and heigth | Diamètre 800 mm ; Hauteur 1950 mm |
Solar station | Wall mounting | 481 x 320 x 190 mm |
Thermal monitoring - DualSun KM2 box | Wall mounting | 95 x 70 x 25 mm |
Central inverter 3 kWc (exemple of a Fronius model) | Wall mounting | 645 x 431 x 204 mm |
DC 3 kWc Box | Wall mounting | 200 x 200 x 110 mm |
AC 4 kWc Box | Wall mounting | 300 x 250 x 140 mm |
Photovoltaic monitoring - Enphase Envoy (To connect on the AC box) | Wall mounting | 213 x 126 x 45 mm |
Overall a volume of 2 m3 is necessary.